Qubit dsDNA Broad Range Assay: Difference between revisions

From Microbial Ecology and Evolution Lab Wiki
Jump to navigation Jump to search
PreDec2022>Eichen
(Created page with "__FORCETOC__ ==Goal:== Quantify DNA samples that will be sent out for sequencing. Qubit Assays produce more accurate and precise results than measurement by NanoDrop spectrophotometer. However, the materials required for the Qubit Assay are limited. Thus, we only perform this assay on samples slated for sequencing (which must match the concentration requirements described by the sequencing companies). ==Materials:== Qubit Fluorometer Invitrogen Qubit dsDNA Broad...")
 
PreDec2022>Eichen
No edit summary
Line 1: Line 1:
__FORCETOC__
__FORCETOC__


==Goal:==
==Goal==
 
Quantify DNA samples that will be sent out for sequencing.  
Quantify DNA samples that will be sent out for sequencing.  


Qubit Assays produce more accurate and precise results than measurement by NanoDrop spectrophotometer. However, the materials required for the Qubit Assay are limited. Thus, we only perform this assay on samples slated for sequencing (which must match the concentration requirements described by the sequencing companies).
Qubit Assays produce more accurate and precise results than measurement by NanoDrop spectrophotometer. However, the materials required for the Qubit Assay are limited. Thus, we '''only perform this assay on samples slated for sequencing''' (which must match the concentration requirements described by the sequencing companies).
 
 
==Materials:==
 
Qubit Fluorometer
Invitrogen Qubit dsDNA Broad Range (BR) Assay Kit (Catalog #Q32850)
Buffer
Reagent / Dye
2 standards
Qubit Assay Tubes, 500ct. (Catalog #Q32856)
 
==Storage:==
Fluorometer: on the bench next to the plate imager
Buffer & Reagent: in a paper box inside the plant cabinet. Both must be stored at room temperature; reagent must be stored in the dark.
Standards: in a plastic Invitrogen Qubit BR Assay bag in the 4C fridge (behind the chemicals box containing Ethidium Bromide, etc). Must be stored at 4C?
Qubit Assay Tubes: autoclaved; in tinfoil-covered glass beakers inside the plant cabinet.


==Materials==
*Qubit Fluorometer
*Invitrogen Qubit dsDNA Broad Range (BR) Assay Kit (Catalog #Q32850)
**Buffer
**Reagent / Dye
**2 standards
*Qubit Assay Tubes, 500ct. (Catalog #Q32856)


==Assay Setup:==
==Storage==
*Fluorometer: on the bench next to the plate imager
*Buffer & Reagent: in a paper box inside the plant cabinet. Both must be stored at room temperature; reagent must be stored in the dark.
*Standards: in a plastic Invitrogen Qubit BR Assay bag in the 4C fridge (behind the chemicals box containing Ethidium Bromide, etc). Must be stored at 4C?
*Qubit Assay Tubes: autoclaved; in tinfoil-covered glass beakers inside the plant cabinet.


==Assay Setup==
Based on the number of samples you wish to quantify, determine master mix (buffer + reagent) volume.
Based on the number of samples you wish to quantify, determine master mix (buffer + reagent) volume.
Use the Qubit Fluorometer’s Reagent Calculator (located at the bottom of the screen display) to calculate volume
Use the Qubit Fluorometer’s Reagent Calculator (located at the bottom of the screen display) to calculate volume
Line 39: Line 34:


Pipette the master mix into the Assay tubes.
Pipette the master mix into the Assay tubes.
190ul / standard tube  
*190ul / standard tube  
198ul / sample tube
*198ul / sample tube


Pipette the DNA into the correct Assay tubes.
Pipette the DNA into the correct Assay tubes.
10ul / standard tube (Standard #1 & Standard #2)
*10ul / standard tube (Standard #1 & Standard #2)
2ul / sample tube
*2ul / sample tube


Vortex each sample for 2-3 seconds & incubate at room temperature for 2 minutes.  
Vortex each sample for 2-3 seconds & incubate at room temperature for 2 minutes.  


==Qubit Fluorometer Quantification:==
==Qubit Fluorometer Quantification:==
From the Home screen, choose dsDNA assay, then Broad Range. Select “Run Standards”, then load Standard #1 & measure. Repeat for Standard #2.  
From the Home screen, choose dsDNA assay, then Broad Range. Select “Run Standards”, then load Standard #1 & measure. Repeat for Standard #2.  


Line 56: Line 49:


==Cleanup:==
==Cleanup:==
Dispose of the used assay tubes & unplug the Qubit fluorometer.
Dispose of the used assay tubes & unplug the Qubit fluorometer.

Revision as of 13:41, 25 July 2022


Goal

Quantify DNA samples that will be sent out for sequencing.

Qubit Assays produce more accurate and precise results than measurement by NanoDrop spectrophotometer. However, the materials required for the Qubit Assay are limited. Thus, we only perform this assay on samples slated for sequencing (which must match the concentration requirements described by the sequencing companies).

Materials

  • Qubit Fluorometer
  • Invitrogen Qubit dsDNA Broad Range (BR) Assay Kit (Catalog #Q32850)
    • Buffer
    • Reagent / Dye
    • 2 standards
  • Qubit Assay Tubes, 500ct. (Catalog #Q32856)

Storage

  • Fluorometer: on the bench next to the plate imager
  • Buffer & Reagent: in a paper box inside the plant cabinet. Both must be stored at room temperature; reagent must be stored in the dark.
  • Standards: in a plastic Invitrogen Qubit BR Assay bag in the 4C fridge (behind the chemicals box containing Ethidium Bromide, etc). Must be stored at 4C?
  • Qubit Assay Tubes: autoclaved; in tinfoil-covered glass beakers inside the plant cabinet.

Assay Setup

Based on the number of samples you wish to quantify, determine master mix (buffer + reagent) volume. Use the Qubit Fluorometer’s Reagent Calculator (located at the bottom of the screen display) to calculate volume Enter the number of samples Always include 2 standards, unless you’ve already run standards that same day Include “overage” (to ensure there is enough for loading)

Set up & label Qubit Assay tubes for your samples + 2 standards.

Make the master mix. Depending on the volume required, I use either a 1.5ml microcentrifuge tube or a 15ml falcon tube Vortex briefly to mix

Pipette the master mix into the Assay tubes.

  • 190ul / standard tube
  • 198ul / sample tube

Pipette the DNA into the correct Assay tubes.

  • 10ul / standard tube (Standard #1 & Standard #2)
  • 2ul / sample tube

Vortex each sample for 2-3 seconds & incubate at room temperature for 2 minutes.

Qubit Fluorometer Quantification:

From the Home screen, choose dsDNA assay, then Broad Range. Select “Run Standards”, then load Standard #1 & measure. Repeat for Standard #2.

Next, measure your samples. Enter the correct volume of sample added to the assay tube (usually 2ul), then load & quantify samples one by one.

Cleanup:

Dispose of the used assay tubes & unplug the Qubit fluorometer.